Semi-electric and variable fans Superior performance Very high efficiency: -27,4% fuel consumption compared to legacy Supra One of the lightest weight in the segment One of the best compactness in the segment High ambient capability – up to +55°C Less maintenance needs & better up-time* *compared to legacy Supra range
Specifications
COOLING CAPACITY | Nominal | |
Diesel – High Speed | 0°C/30°C | 12010 W |
-20°C/30°C | 6690 W | |
Diesel – Low Speed | 0°C/30°C | 9900 W |
-20°C/30°C | 6350 W | |
Standby – 400V/3/50 Hz | 0°C/30°C | 10170 W |
-20°C/30°C | 5980 W |
HEATING CAPACITY | ||
Diesel | 10840 W | |
Standby – 400V/3/50 Hz | 5540 W |
AIRFLOW | ||
Diesel | 3074 m3/hr | |
400V/3/50Hz | 3074 m3/hr |
ATP COMPLIANT | ||
– | M1070 |
WEIGHT | ||
– | 502 kg |
DIMENSIONS | ||
Height | 615 mm | |
Width | 1915 mm | |
Depth | 815 mm |
BOX SIZE RECOMMENDATION | ||
+0°C | +30°C | 85 m3 |
+40°C | 68 m3 | |
-20°C | +30°C | 74 m3 |
+40°C | 58 |
SOUND EMISSION | ||
Sound Power | Power Lwa | 97 dB |
Diesel – High Speed | Pressure | 68.4 dB |
Standby – 400V/3/50 Hz | Pressure | 63.4 dB |
COMPONENTS | ||
Engine | Displacement | 1123 cc |
# cylinders | 3 | |
Motor | Voltage | 400V/3/50Hz |
Power | 7.5 kW | |
Compressor | Techno | Reciprocating |
Model | 05K4 | |
Controls | APX |
REFRIGERANT | ||
Refrigerant | Type | R452A |
Charge | 3.9 kg |