You are here:
Supra 1250 MT
Total flexibility for multi-product deliveries with ultra-slim evaporators that can be adapted to large configuration requirement
Benefits
Exceptional performance characteristics
High reliability
Improved service accessibility
Large choice of evaporators
Specifications
Refrigeration Capacity
(System net cooling capacity under A.T.P. Conditions at 30° C ambient)
Evaporator | MTS 700 | MTS 1100 | MTS 1450 | MTS 2200 | MTD 1450 | MTD 2200 |
Nominal capacity (-20°C/30°C) (W) | 3 400 | 5 000 | 5 700 | 7 200 | 5 600 | 11 400 |
Capacity on engine power 0°C (W) | 7 200 | 8 550 | 9 500 | 10 500 | 8 950 | 11 400 |
Capacity on engine power -20°C (W) | 3 400 | 5 000 | 5 700 | 5 850 | 5 600 | 6 300 |
Capacity on electrical stand by 0°C (W) | 5 900 | 8 100 | 8 900 | 9 600 | 8 000 | 10 000 |
Capacity on electrical stand by -20°C (W) | 3 200 | 4 800 | 5 350 | 5 450 | 5 350 | 5 950 |
Heating Capacity
MTS 700 | MTS 1100 | MTS 1450 | MTS 2200 | MTD 1450 | MTD 2200 | |
Diesel High speed 18°C/-18°C (W) | 4 680 | 4 710 | 4 890 | 5 200 | 4 890 | 5 200 |
Standby 18°C/-18°C (W) | 4 270 | 4 320 | 4 530 | 4 770 | 4 530 | 4 770 |
Airflow
(High speed engine operation)
MTS 700 | MTS 1100 | MTS 1450 | MTS 2200 | MTD 1450 | MTD 2200 | |
(AMCA 21085) m3/hr | 1 100 | 2 100 | 2 400 | 3 500 | 2 350 | 3 600 |
Weight
(Including battery)
S version | 586 kg |
Engine
Model | CT3-69TV |
Displacement | 1123 cm3 |
n° of cylinders | 3 |
Maintenance Interval | 1000 hrs |
Compressor
Model | 05G |
Displacement | 600 cm3 |
n° of cylinders | 6 |
Electrical Stand by Motor
Voltage / Phase / Frequency | 230/400/3/50 Hz |
Rating | 9 kW |
Refrigerant
Type | R-404A, R-452A |
Charge | Depending on configuration |
Sound Pressure
Standard | |
High speed | 69,2 dBA |
Low speed | 65,7 dBA |
Standby | 62,2 dBA |
Unit
Dimensions | 971 x 1995 x 684 mm |
Body opening | L 100 x H 100 mm |